Rat IgG1, kappa Isotype Control Antibody, Clone RTK2071

Rat monoclonal IgG1, kappa isotype control antibody

产品号 #60075_C

Rat monoclonal IgG1, kappa isotype control antibody

概述

The RTK2071 antibody (IgG1, kappa) is suitable for use as an isotype-matched control antibody in several applications to estimate the degree of non-specific binding by an antigen-specific antibody. Ideally, the isotype control should have the same subclass of heavy chain (IgA, IgD, IgE, IgG, or IgM) and light chain (kappa or lambda) as the specific antibody being used. If a conjugated antibody is used, an isotype control conjugated to the same molecule (e.g. fluorochrome) should be chosen. The use of an appropriate isotype control helps confirm the specificity of the antigen-specific antibody and indicates non-specific binding that may result from binding to Fc receptors or other cell components.

This antibody clone has been verified for use as an isotype control antibody for assessing non-specific binding to cells in applications such as flow cytometry and immunofluorescence microscopy applications (surface and intracellular staining).

Subtype
Isotype Controls
 
Target Antigen
IgG1 Isotype Control
 
Alternative Names
Not applicable
 
Conjugation
Alexa Fluor 488, APC, Biotin, FITC, PE, Unconjugated
 
Host Species
Rat
 
Cell Type
Other
 
Species
Human, Mouse, Non-Human Primate, Other, Rat
 
Application
Flow Cytometry, Functional Assay, Immunocytochemistry, Immunofluorescence, Immunohistochemistry, Immunoprecipitation, Western Blotting
 
Area of Interest
Immunology
 
Clone
RTK2071
 
Gene ID
Not applicable
 
Isotype
IgG1, kappa
 

Data Figures

Data for unconjugated

Figure 1. Data for Unconjugated

(A) Flow cytometry analysis of C57BL/6 mouse splenocytes (gated on lymphocytes) labeled with Rat IgG1, kappa Isotype Control Antibody, Clone RTK2071, followed by a mouse anti-rat IgG1 antibody, FITC and Anti-Mouse CD45 Antibody, Clone 30-F11, PE (Catalog #60030PE). (B) Flow cytometry analysis of C57BL/6 mouse splenocytes (gated on lymphocytes) labeled with Anti-Mouse CD25 Antibody, Clone PC61.5 (Catalog #60009), followed by a mouse anti-rat IgG1 antibody, FITC and Anti-Mouse CD45 Antibody, Clone 30-F11, PE.

Data for Alexa Fluor® 488-Conjugated

Figure 2. Data for Alexa Fluor® 488-Conjugated

(A) Flow cytometry analysis of C57BL/6 mouse splenocytes (gated on lymphocytes) labeled with Rat IgG1, kappa Isotype Control Antibody, Clone RTK2071, Alexa Fluor® 488 and Anti-Mouse CD3e Antibody, Clone 145-2C11, APC (Catalog #60015AZ). (B) Flow cytometry analysis of C57BL/6 mouse splenocytes (gated on lymphocytes) labeled with an anti-mouse CD25 antibody, Alexa Fluor® 488 and Anti-Mouse CD3e Antibody, Clone 145-2C11, APC.

Data for APC-Conjugated

Figure 3. Data for APC-Conjugated

(A) Flow cytometry analysis of C57BL/6 mouse splenocytes (gated on lymphocytes) labeled with Rat IgG1, kappa Isotype Control Antibody, Clone RTK2071, APC and Anti-Mouse CD45 Antibody, Clone 30-F11, PE (Catalog #60030PE). (B) Flow cytometry analysis of C57BL/6 mouse splenocytes (gated on lymphocytes) labeled with Anti-Mouse CD25 Antibody, Clone PC61.5, APC (Catalog #60009AZ) and Anti-Mouse CD45 Antibody, Clone 30-F11, PE.

Data for Biotin-Conjugated

Figure 4. Data for Biotin-Conjugated

(A) Flow cytometry analysis of C57BL/6 mouse splenocytes (gated on lymphocytes) labeled with Rat IgG1, kappa Isotype Control Antibody, Clone RTK2071, Biotin followed by streptavidin (SAV) APC and Anti-Mouse CD3e Antibody, Clone 145-2C11, PE (Catalog #60015PE). (B) Flow cytometry analysis of C57BL/6 mouse splenocytes (gated on lymphocytes) labeled with Anti-Mouse CD25 Antibody, Clone PC61.5, Biotin (Catalog #60009BT) followed by SAV APC and Anti-Mouse CD3e Antibody, Clone 145-2C11, PE.

Data for FITC-Conjugated

Figure 5. Data for FITC-Conjugated

(A) Flow cytometry analysis of C57BL/6 mouse splenocytes (gated on lymphocytes) labeled with Rat IgG1, kappa Isotype Control Antibody, Clone RTK2071, FITC and Anti-Mouse CD3e Antibody, Clone 145-2C11, APC (Catalog #60015AZ). (B) Flow cytometry analysis of C57BL/6 mouse splenocytes (gated on lymphocytes) labeled with an anti-mouse CD25 antibody, FITC and Anti-Mouse CD3e Antibody, Clone 145-2C11, APC.

Data for PE-Conjugated

Figure 6. Data for PE-Conjugated

(A) Flow cytometry analysis of C57BL/6 mouse splenocytes (gated on lymphocytes) labeled with Rat IgG1, kappa Isotype Control Antibody, Clone RTK2071, PE and Anti-Mouse CD3e Antibody, Clone 145-2C11, APC (Catalog #60015AZ). (B) Flow cytometry analysis of C57BL/6 mouse splenocytes (gated on lymphocytes) labeled with Anti-Mouse CD25 Antibody, Clone PC61.5, PE (Catalog #60009PE) and Anti-Mouse CD3e Antibody, Clone 145-2C11, APC.

Protocols and Documentation

Find supporting information and directions for use in the Product Information Sheet or explore additional protocols below.

Document Type
Product Name
Catalog #
Lot #
Language
Catalog #
60075AD
Lot #
All
Language
English
Catalog #
60075AZ
Lot #
All
Language
English
Catalog #
60075BT, 60075BT.1
Lot #
All
Language
English
Catalog #
60075PE
Lot #
All
Language
English
Catalog #
60075, 60075.1
Lot #
All
Language
English
Document Type
Safety Data Sheet
Catalog #
60075AD
Lot #
All
Language
English
Document Type
Safety Data Sheet
Catalog #
60075AZ
Lot #
All
Language
English
Document Type
Safety Data Sheet
Catalog #
60075BT, 60075BT.1
Lot #
All
Language
English
Document Type
Safety Data Sheet
Catalog #
60075PE
Lot #
All
Language
English
Document Type
Safety Data Sheet
Catalog #
60075, 60075.1
Lot #
All
Language
English

Applications

This product is designed for use in the following research area(s) as part of the highlighted workflow stage(s). Explore these workflows to learn more about the other products we offer to support each research area.

Resources and Publications

Educational Materials (2)

Legal Statement: Alexa Fluor is a registered trademark of Life Technologies Corporation. Antibodies conjugated to Alexa Fluor® are licensed for internal research use only and sale is expressly conditioned on the buyer not using the antibody for manufacturing, performing a service or medical test, or otherwise generating revenue. For use other than research, contact Life Technologies Corporation, 5791 Van Allen Way, Carlsbad, CA 92008 USA or outlicensing@lifetech.com. PRODUCTS ARE FOR RESEARCH USE ONLY AND NOT INTENDED FOR HUMAN OR ANIMAL DIAGNOSTIC OR THERAPEUTIC USES UNLESS OTHERWISE STATED. FOR ADDITIONAL INFORMATION ON QUALITY AT STEMCELL, REFER TO WWW.STEMCELL.COM/COMPLIANCE.
版权 © 2025 STEMCELL Technologies 技术有限公司。保留所有权利。