小鼠IgG1 (kappa Isotype Control Antibody,克隆MOPC-21

小鼠单克隆IgG1, kappa同型控制抗体

产品号 #(选择产品)

产品号 #60070_C

小鼠单克隆IgG1, kappa同型控制抗体

概述

MOPC-21抗体(IgG1, kappa)适合作为同型匹配对照抗体在多种应用中用于估计抗原特异性抗体的非特异性结合程度。理想情况下,同型对照应与所使用的特异性抗体具有相同的重链(IgA、IgD、IgE、IgG或IgM)和轻链(kappa或lambda)亚类。如果使用偶联抗体,则应选择与相同分子(如荧光染料)偶联的同型对照物。使用适当的同型对照有助于确认抗原特异性抗体的特异性,并指出与Fc受体或其他细胞成分结合可能导致的非特异性结合。

该抗体克隆已被证实可作为同型对照抗体,用于流式细胞术和免疫荧光显微镜应用(表面和细胞内染色)中评估与细胞的非特异性结合。

Subtype
Isotype Controls
 
Target Antigen
IgG1 Isotype Control
 
Alternative Names
Not applicable
 
Conjugation
Alexa Fluor 488, APC, FITC, PE, Unconjugated
 
Host Species
Mouse
 
Cell Type
Other
 
Species
Human, Mouse, Non-Human Primate, Other, Rat
 
Application
Flow Cytometry, Functional Assay, Immunocytochemistry, Immunofluorescence, Immunohistochemistry, Immunoprecipitation, Western Blotting
 
Area of Interest
Immunology
 
Clone
MOPC-21
 
Gene ID
Not applicable
 
Isotype
IgG1, kappa
 

Data Figures

Data for Unconjugated

Figure 1. Data for Unconjugated

(A) Flow cytometry analysis of dendritic cells derived from human peripheral blood mononuclear cells (PBMCs). Cells were processed with the EasySep™ Human CD14 Positive Selection Kit (Catalog #18058) and labeled with Mouse IgG1, kappa Isotype Control Antibody, Clone MOPC-21, followed by a rat anti-mouse IgG1 antibody, PE (solid line histogram). Filled histogram shows labeling with a mouse IgG1, kappa positive control antibody (Anti-Human CD83 Antibody, Clone HB15e, Catalog #60107) followed by a rat anti-mouse IgG1 antibody, PE.(B) Human embryonic stem (ES) cells were cultured using mTeSR™1 (Catalog #05850) on Corning® Matrigel®-coated glass slides, then fixed and labeled with Mouse IgG1, kappa Isotype Control Antibody, Clone MOPC-21, followed by goat anti-mouse IgG, FITC (inset) or with a positive control antibody of the same isotype, Anti-Human SSEA-5 Antibody, Clone 8e11 (Catalog #60063), followed by goat anti-mouse IgG, FITC (green).

Data for Alexa Fluor® 488-Conjugated

Figure 2. Data for Alexa Fluor® 488-Conjugated

(A) Flow cytometry analysis of dendritic cells derived from human peripheral blood mononuclear cells (PBMCs). Cells were processed with the EasySep™ Human CD14 Positive Selection Kit (Catalog #18058) and labeled with Mouse IgG1, kappa Isotype Control Antibody, Clone MOPC-21, Alexa Fluor® 488 (solid line histogram). Filled histogram shows labeling with a mouse IgG1, kappa positive control antibody (Anti-Human CD83 Antibody, Clone HB15e, Alexa Fluor® 488, Catalog #60107AD). (B) Human induced pluripotent stem (iPS) cells were cultured using mTeSR™1 (Catalog #05850) on Corning® Matrigel®-coated glass slides, then fixed and labeled with Mouse IgG1, kappa Isotype Control Antibody, Clone MOPC-21, Alexa Fluor® 488 (inset) or with a positive control antibody of the same isotype, Anti-Human SSEA-5 Antibody, Clone 8e11, Alexa Fluor® 488 (Catalog #60063AD, green).

Data for APC-Conjugated

Figure 3. Data for APC-Conjugated

Flow cytometry analysis of dendritic cells derived from human peripheral blood mononuclear cells (PBMCs). Cells were processed with the EasySep™ Human CD14 Positive Selection Kit (Catalog #18058) and labeled with Mouse IgG1, kappa Isotype Control Antibody, Clone MOPC-21, APC (solid line histogram). Filled histogram shows labeling with a mouse IgG1, kappa positive control antibody (Anti-Human CD83 Antibody, Clone HB15e, APC, Catalog #60107AZ).

Data for Biotin-Conjugated

Figure 4. Data for Biotin-Conjugated

Flow cytometry analysis of dendritic cells derived from human peripheral blood mononuclear cells (PBMCs). Cells were processed with the EasySep™ Human CD14 Positive Selection Kit (Catalog #18058) and labeled with Mouse IgG1, kappa Isotype Control Antibody, Clone MOPC-21, Biotin followed by streptavidin (SAV) APC (solid line histogram). Filled histogram shows labeling with a mouse IgG1, kappa positive control antibody (Anti-Human CD83 Antibody, Clone HB15e, Biotin, Catalog #60107BT) followed by SAV APC.

Data for FITC-Conjugated

Figure 5. Data for FITC-Conjugated

Flow cytometry analysis of dendritic cells derived from human peripheral blood mononuclear cells (PBMCs). Cells were processed with the EasySep™ Human CD14 Positive Selection Kit (Catalog #18058) and labeled with Mouse IgG1, kappa Isotype Control Antibody, Clone MOPC-21, FITC (solid line histogram). Filled histogram shows labeling with a mouse IgG1, kappa positive control antibody (Anti-Human CD83 Antibody, Clone HB15e, FITC, Catalog #60107FI).

Data for PE-Conjugated

Figure 6. Data for PE-Conjugated

(A) Flow cytometry analysis of dendritic cells derived from human peripheral blood mononuclear cells (PBMCs). Cells were processed with the EasySep™ Human CD14 Positive Selection Kit (Catalog #18058) and labeled with Mouse IgG1, kappa Isotype Control Antibody, Clone MOPC-21, PE (solid line histogram). Filled histogram shows labeling with a mouse IgG1, kappa positive control antibody (Anti-Human CD83 Antibody, Clone HB15e, PE, Catalog #60107PE). (B) Human induced pluripotent stem (iPS) cells were cultured using mTeSR™1 (Catalog #05850) on Corning® Matrigel®-coated glass slides, then fixed and labeled with Mouse IgG1, kappa Isotype Control Antibody, Clone MOPC-21, PE (inset) or with a positive control antibody of the same isotype, Anti-Human SSEA-5 Antibody, Clone 8e11, PE (Catalog #60063PE, red).

Data for PE-Conjugated

Figure 7. Data for PS-Conjugated

Flow cytometry analysis of human peripheral blood mononuclear cells (PBMCs) labeled with Mouse IgG1, kappa Isotype Control Antibody, Clone MOPC- 21, PerCP-Cy5.5 (solid line histogram). Filled histogram shows labeling with a mouse IgG1, kappa positive control antibody (Anti-Human CD45 Antibody, Clone HI30, PerCP-Cy5.5; Catalog #60018PS).

Protocols and Documentation

Find supporting information and directions for use in the Product Information Sheet or explore additional protocols below.

Document Type
Product Name
Catalog #
Lot #
Language
Catalog #
60070AD, 60070AD.1
Lot #
All
Language
English
Catalog #
60070AZ, 60070AZ.1
Lot #
All
Language
English
Catalog #
60070BT.1
Lot #
All
Language
English
Catalog #
60070FI, 60070FI.1
Lot #
All
Language
English
Catalog #
60070PE, 60070PE.1
Lot #
All
Language
English
Catalog #
60070PS
Lot #
All
Language
English
Catalog #
60070.1, 60070
Lot #
All
Language
English
Document Type
Safety Data Sheet
Catalog #
60070AD, 60070AD.1
Lot #
All
Language
English
Document Type
Safety Data Sheet
Catalog #
60070AZ, 60070AZ.1
Lot #
All
Language
English
Document Type
Safety Data Sheet
Catalog #
60070BT.1
Lot #
All
Language
English
Document Type
Safety Data Sheet
Catalog #
60070FI, 60070FI.1
Lot #
All
Language
English
Document Type
Safety Data Sheet
Catalog #
60070PE, 60070PE.1
Lot #
All
Language
English
Document Type
Safety Data Sheet
Catalog #
60070PS
Lot #
All
Language
English
Document Type
Safety Data Sheet
Catalog #
60070.1, 60070
Lot #
All
Language
English

Applications

This product is designed for use in the following research area(s) as part of the highlighted workflow stage(s). Explore these workflows to learn more about the other products we offer to support each research area.

Resources and Publications

Educational Materials (2)

Publications (1)

Trend of telomerase activity change during human iPSC self-renewal and differentiation revealed by a quartz crystal microbalance based assay. Zhou Y et al. Scientific reports 2014 NOV

Abstract

Telomerase plays an important role in governing the life span of cells for its capacity to extend telomeres. As high activity of telomerase has been found in stem cells and cancer cells specifically, various methods have been developed for the evaluation of telomerase activity. To overcome the time-consuming procedures and complicated manipulations of existing methods, we developed a novel method named Telomeric Repeat Elongation Assay based on Quartz crystal microbalance (TREAQ) to monitor telomerase activity during the self-renewal and differentiation of human induced pluripotent stem cells (hiPSCs). TREAQ results indicated hiPSCs possess invariable telomerase activity for 11 passages on Matrigel and a steady decline of telomerase activity when differentiated for different periods, which is confirmed with existing golden standard method. The pluripotency of hiPSCs during differentiation could be estimated through monitoring telomerase activity and compared with the expression levels of markers of pluripotency gene via quantitative real time PCR. Regular assessment for factors associated with pluripotency or stemness was expensive and requires excessive sample consuming, thus TREAQ could be a promising alternative technology for routine monitoring of telomerase activity and estimate the pluripotency of stem cells.

更多信息

更多信息
Species Human, Mouse, Non-Human Primate, Other, Rat
Clone MOPC-21
Gene Id Not applicable
Alternative Names Not applicable
Isotype IgG1, kappa
Legal Statement: Alexa Fluor is a registered trademark of Life Technologies Corporation. Antibodies conjugated to Alexa Fluor® are licensed for internal research use only and sale is expressly conditioned on the buyer not using the antibody for manufacturing, performing a service or medical test, or otherwise generating revenue. For use other than research, contact Life Technologies Corporation, 5791 Van Allen Way, Carlsbad, CA 92008 USA or outlicensing@lifetech.com. PRODUCTS ARE FOR RESEARCH USE ONLY AND NOT INTENDED FOR HUMAN OR ANIMAL DIAGNOSTIC OR THERAPEUTIC USES UNLESS OTHERWISE STATED. FOR ADDITIONAL INFORMATION ON QUALITY AT STEMCELL, REFER TO WWW.STEMCELL.COM/COMPLIANCE.
版权 © 2025 STEMCELL Technologies 技术有限公司。保留所有权利。